CRYOVATION

Fill-Free


Fill-Free™




OVERVIEWFill-Free 1.0 – Single Product (Pure Oxygen) Semi Automated SystemThe Fill-Free 1.0™ allows the operator to enter the desired DOT fill pressure  and vacuum level, on either the Manifold “A” or “B” set-up screen, and start the fill process. The cylinder temperature is monitored and the ultimate fill pressure is automatically calculated and displayed – the same great features we’ve offered in our fully automated system for the past 15 years.The operator is alerted at zero vent pressure, again for leak check, and a third time when the vacuum level is attained. Once full, the pump is automatically stopped and the operator is again alerted.An optional high-pressure valve may be installed to shut off when full  pressure is attained.Fill-Free 2.5 and 3.0 – Mix Gas Semi Automated SystemFill-Free 3.0 – Gravimetric (fill by gram weight)Fill-Free 4.0 – Fully Automated Pure Oxygen Fill SystemCompletely automatic, unattended filling of high pressure oxygen cylinders to 3000 PSIControl system with Mitsubishi PLC controller for all input and output interfacing with all other major components. Ladder logic program is designed, installed, tested and design protected by CryoVationPC Workstation with full-color, “touch-screen” display and WonderWare® (windows based) software. 15” touch-screen monitor. CryoVation designed software for cylinder filling application.Enclosure, NEMA 4, housing all control components, free standing, with pressure transducers, vacuum transducers and thermocouples.Control valve manifold with CPV bronze valves.Audible or visual signaling of leak check requirement.Ethernet connection for remote monitoring.Batch data sheet with required FDA information.Control panel for manual operation and control.Fill-Free 5.0 – Automatic Cylinder Filling Control SystemFill-Free 5.0™ Fully Automated Gravimetric Filling System for pure and mixed gasesPLC controlledProgram is designed, installed, tested by CryoVationFull-color 15” “touch-screen” display4500 PSI Reference cylindersEnclosure – NEMA 4, housing all control componentsAir-Actuated Control valve manifoldComplete manual over-ride capabilityEthernet connection for remote monitoring.Batch data reporting

Samee Corporation Ltd.

+82(0)31-492-1691

jwy3e@daum.net

경기도 안산시 단원구 산단로 341 정우벤처 2차 401호~403호 (본사)

© Copyright 2025. All Rights Reserved by sameee

Samee Corporation Ltd.

+82(0)31-492-1691

jwy3e@daum.net

경기도 안산시 단원구 산단로 341 정우벤처 2차 401호~403호 (본사)

© Copyright 2025. All Rights Reserved by sameee

Samee Corporation Ltd.

+82(0)31-492-1691

jwy3e@daum.net

경기도 안산시 단원구 산단로 341 정우벤처 2차 401호~403호 (본사)

© Copyright 2025. All Rights Reserved by sameee